● Model: BM-DI/V DC Current Isolator
● Input: DC4-20mA; Output: 0-5V
● Power: DC24V or AC220V; Class 0.5
● 35mm Din rail installation
● Plug-in terminal; Using magnetic isolation technology
● Used in automation systems in the power, railway, petrochemical, metallurgical, food, warehousing and similar industries

General
Analogue signal transducer BM series can measure electrical parameters (e.g. current and voltage) and non-electrical parameters (e.g. temperature and resistance) rapidly and accurately and isolate and convert measured values to standard analogue output signal. It can be not only connected directly with pointer gauges and digital display meters but also integrated with automatic control instruments (e.g. PLC), various A/D converters and computer systems.
They can used in automation systems in the power, railway, petrochemical, metallurgical, food, warehousing and similar industries.
Specification
Dimension
Product Selection
Outline Size
Structure
Model
|
Input form
|
Input range
|
Output range
|
Auxiliary supply
|
Output settings
|
Other features
|
BM-DI/IS
|
Direct current
|
0-1mA
0-20mA 4-20mA 0-5A |
4-20mA
|
/
|
2-wire 8.5-40VDC
|
Powered by output circuit
|
BM-AI/IS
|
Alternating current
|
0-1A, 0-5A
|
4-20mA
|
/
|
2-wire 8.5-40VDC
|
Powered by output circuit
|
BM-DIS/I
|
Direct current
|
4-20mA
|
4-20mA
|
/
|
Self-powered by input circuit
|
|
BM-DI/II BM-DV/II BM-DI/IV BM-DV/IV
|
4-20mA
0-5V |
4-20mA
|
24VDC
|
Independent two circuits
|
|
|
BM-DI/I
BM-DI/V |
4-20mA
0-20mA |
4-20mA,0-20mA;
0-10V;0-5V |
24VDC
|
4-wire
|
|
|
BM-DI/J
|
0-20mA
|
Two relays controlled by setting point
|
110/220V AC, DC
|
2 NO contact groups
|
|
|
BM-DV/IS
|
Direct voltage
|
0-10V; 0-5V
|
4-20mA
|
/
|
2-wire 8.5-40VDC
|
Powered by output circuit
|
BM-DV/I
BM-DV/V |
0-10V;0-5V
|
4-20mA,4-20mA,0-20mA;
0-10V;0-5V |
24VDC
|
4-wire
|
|
|
BM-DV/J
|
0-10V
|
Two relays controlled by setting point
|
110/220V AC, DC
|
2 NO contact groups
|
|
|
BM-AV/IS
|
Alternating voltage
|
0-125V AC,0-250V AC,0-450V AC
|
4-20mA
|
/
|
2-wire 8.5-40VDC
|
Powered by output circuit
|
BM-TC/I BM-TC/V
|
Thermocouple
Thermal resistance |
K,J graduation 0-250℃; 0-500℃ 1- 0-1000℃; 0-1200℃
|
4-20mA
|
24VDC
|
4-wire
|
RS485 communication output
|
BM-TR/IS
|
Thermal resistance
|
Pt100
0-50℃ ;0-100'C 0-150℃; 0-200℃ 0-250℃; 0-300℃ |
4-20mA
|
/
|
2-wire 8.5-40VDC
|
Powered by output circuit
|
BM-TR/I
|
24VDC
|
4-wire
|
|
|||
BM-R/IS
|
Resistance
|
0-100Ω; 0-lkΩ
0-5kΩ; 0-10kΩ |
4-20mA
|
/
|
2-wire 8.5-40VDC
|
Powered by output circuit
|
BM-VR/IS
|
Potentiometer
|
0 ~350Ω(~10kΩ)
|
4-20mA
|
/
|
2-wire 8.5-40VDC
|
Powered by output circuit
|