A Type Earth Leakage Relay ASJ10-LD1A

● The measurement of A-type after-current;

● The streamer display of current percentage;

● The setting of rated residual action current;

● The setting of non-driving time of limitation;

● Two-pair relay output;

● Possessing the function of on-the-spot and long-distance testing and resetting.

  • product detail
  • PARAMETER
  • FAQ

General

ASJ Series of action relay of after-current, low-voltage circuit break or low-voltage contactor can be made up for combined after-current production device, which is mainly applied for the TT and TN system distributing circuit with the alternating current 50Hz, the rated voltage 400V or below.
ASJ Series of action relay of after-current is applied in the earth fault protection for the electric circuit, so as to prevent the equipment damage and the fire accident of electric equipment caused by the ground fault current, moreover, it also can provide indirect contact protection against the electric shock risk.


Function

Type
Function


ASJ20-LD1C
AC type residual current
Over current alarm
Rated residual operated current can be set
Limited non-driving time can be set
2 relays output(1 NC contact, 1 normal changeover contact)
With local/remote "test" and "reset" functions


ASJ20-LD1A
A type residual current measurement
Current percentage light bar indication(30%, 50%, 70%, TRIP)
Rated residual operated current can be set
Limited non-driving time can be set
2 relays output(1 NO contact, 1 normal changeover contact)
With local/remote/automatic "test" and "reset" functions


ASJ10-LD1C
AC type residual current
Over current alarm
Rated residual operated current can be set
Limited non-driving time can be set
2 relays output(1 NC contact, 1 normal changeover contact)
With local/remote "test" and "reset" functions


ASJ10-LD1A
A type residual current measurement
Current percentage light bar indication(30%, 50%, 70%, TRIP)
Rated residual operated current can be set
Limited non-driving time can be set
2 relays output(1 NO contact, 1 normal changeover contact)
With local/remote/automatic "test" and "reset" functions



Dimension

Appearance and hole size of installation (ASJ10-LD1C/ASJ10-LD1A)


Installation mode of magnetic ring


Wiring



Typical Connection


Collect switch signals by PLC and upload to monitoring system


Technical Parameter
Value
Input
Rated residual
operated current I△n
0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30(A)
Limitation non driving time
0,0.06, 0.1, 0.2, 0.3, 0.5, 0.8, 1, 4, 10(S)
Rated non-action residual current
50%I△n
Frequency
50Hz±5Hz
Tripping accuracy
-20% ~ -10%I△n
Output
Output mode
1 normal changeover contact
Contact capacity
AL1: 8A 250VAC 5A 30VDC
AL2: 6A 250VAC 5A 30VDC
Reset mode
Local, remote, automatic
Auxiliary power supply

Voltage range AC/DC85~270V
Power consumption ≤5W
Power frequency withstand voltage
The effective value of alternating current between the power supply, input and output: 2kV/1min


Q: How many wires can be passed through a residual current transformer?

Can I just put one firewire? Can I just pass firewire of A, B, C through the sensor?

A: In a three-phase four-wire system, 4 wires should be used. You can’t just pass a firewire, and A, B, C, N should all be passed through the Residual current transformer. A suitable transformer should be selected according to the wire diameter and rated current on site.



Q: The wire of three phase dand four wire is very thick. Can a measuring sensor be fitted to each phase, and four sensor secendary be passed through small hole size wires. Then connect the residual current relay?

A: Not recommended. By this plan, at the moment of starting the high-power and high-frequency equipment, the vector sum of the output current of three-phase four-wire measurement transformer is not zero (directly measured is 0), which can easily lead to malfunction and tripping.



Q: Can open-type residual current transformers be used in the renovation project?

A: For reconstruct projects, if the wire diameter of the line is less than 100mm, open-type residual current transformers can be used. It is not recommended to use open-type residual current transformers larger than this aperture, because the measurement accuracy of the large aperture sensor is poor.



Q: Why does the residual current relay operate as soon as it is powered on?

A: Reason one may be wiring error;  Another may be wrong product selection.



Q: After power-off the ASJ residual current relay, the breaker will trip-out. What's the reason for this phenomenon?

A: This phenomenon is that the breaker will trip-out after the protected power supply is cut off; the other is to protect the line when undergoing dual power switching.

ASJ series residual current relay is the type that automatically recovers and resets when the auxiliary power fails.According above-mentioned conditions, the instrument can be selected as the type that does not automatically act when the power fails.



Q: What does In:100A mean on the panel? Can it be removed?

A: In means rated current and cannot be removed. It is clearly stipulated in 4.2.2.2 and 5.1 of GB/T 22387-2016, the panel needs to be marked with the rated current or the size of the hole of the residual current transformer.




Feedback form contact with us
Related Product
AC Type Residual Current Relay ASJ10-LD1C
AC Type Residual Current Relay ASJ10-LD1C
You can buy good quality AC Type Residual Current Relay ASJ10-LD1C, we are the best distributor from...
Learn More
Panel Mounted Ground Fault Relay ASJ20-LD1A
Panel Mounted Ground Fault Relay ASJ20-LD1A
Quality Panel Mounted Ground Fault Relay ASJ20-LD1A suppliers & exporter - all products made in ...
Learn More
Rail Mounted Earth Protection Relay ASJ20-LD1C
Rail Mounted Earth Protection Relay ASJ20-LD1C
Hot Rail Mounted Earth Protection Relay ASJ20-LD1C - Acrel is the best Rail Mounted Earth Protection...
Learn More
Product Catalog