Low-voltage Earth Fault Relay ALP220-EF

● Integrate leakage, overload and earth fault protection

Inverse-time Overcurrent & Earth-fault  (51/51G)

Three-stage Definite-time Overcurrent & Earth-fault (50/51 50N/51N)

Current Unbalance Protection (46)

Residual Current Monitoring (50G)

Modbus-RTU  communication; LCD display

Suitable for AC 690V and below low-voltage switchgear, distribution panels and feeder circuits.


  • product detail
  • PARAMETER
  • Functional Configuration

General

Acrel ALP220-EF Earth Fault Overcurrent Relay is designed for low-voltage applications (up to 380 V) where it is necessary to monitor the system's ground current and provide protection when the ground current exceeds the permissible limit. This relay features an LCD display, Modbus-RTU communication capability, system current measurement, three- phase current overcurrent protection, ground current overcurrent protection, residual current measurement, residual current overcurrent protection, fault logging, and event logging functions.


Front Panel


Dimension

External Dimension & Side View Dimension & Installation Opening Dimension



Wiring

Three-Phase Four-Wire Connection


Three-Phase Three-Wire Connection


Application

Technical parameter Qualification
Accessory power supply Voltage range AC/DC 85~265V
Power dissipation
Import Current specifications ABCN (4-channel): 1A/5A 10%Ie~1000%Ie ±2%
Residual current
specification
30mA-1000mA ±2%
Frequency 45Hz-65Hz ±0.2Hz
Output Output method Dual-channel single-pole double-throw switch
Output capacity Resistive load; AC 250 V 5 A / DC 30 V 5 A
Installation and
Usage Environment
Workplace Scenario No direct exposure to rain or snow; no corrosive gases; no severe vibration
Relative humidity ≤95% RH, no condensation
Working temperature -20℃~+70℃
Storage temperature -40℃~+70℃
Height ≤2000m
Way to install Embedded installation: 88×88 (mm)
Levels of protection Panel: IP54; Terminals: IP20
Security classification EMC Level III
Note: Frequency accuracy measurement error range = Accuracy range; for the accuracy measurement of otherparameters, the full-scale error calculation method is applied: Error range = Full scale × Accuracy percentage.


Function Standard configuration Optional
Measurement Function Three-phase alternating current
Neutral conductor current
Residual current
Defencive function Inverse-time overcurrent protection
Inverse Time Grounding
Three-stage time-delayed
overcurrent protection
Three-stage time-delayed
ground fault protection
Current imbalance
Leakage current
Communication Function Modbus-RTU
Digital output function 2 Single-pole double-throw switch
Record Function 20 Single fault record
20 Event Record
Display Function Liquid-crystal display
Setpoint Setting Function
Operation Panel Modification
Communication Amendment


Feedback form contact with us
Related Product
Low Voltage Motor Protector ARD2(L)
Low Voltage Motor Protector ARD2(L)
As the largest Motor Circuit Protector,Motor Protection Relay,Low Voltage Motor Protector manufactur...
Learn More
Motor Circuit Protector ARD2F
Motor Circuit Protector ARD2F
Hot Motor Circuit Protector ARD2F - Acrel is the best Motor Circuit Protector ARD2F supplier in Chin...
Learn More
Digital Electric Motor Protector ARD3M
Digital Electric Motor Protector ARD3M
Acrel is one of the toppest Motor Circuit Protector,Motor Protection Relay,Digital Electric Motor Pr...
Learn More
Product Catalog