General
Medical isolation power distribution cabinet is a cabinet with a local IT sytems designed for medical group II power supply requirements. Insulation monitoring device installed in IT system monitor insulation condition of the system. Each output circuit has circuit breaker with short circuit protection function, the output circuit in TN-S system has a circuit breaker with leakage protection.
Products are divided into GGF-O series three-phase isolated power cabinet, and GGF-I series single-phase isolated power supply cabinet. According to the number of input voltage phases, these products can satisfy the power safety and reliability requirements of various operating room and intersive care unit, and the products meet IEC standard.
Specification
Technical Parameters |
GGF-IXG |
GGF-IXQ |
GGF-IXF |
GGF-OXG |
GGF-OXQ |
GGF-OXF |
Rated voltage |
220VAC |
380V/220V AC |
||||
Rated Capacity |
3.15/5/6.3/8/10 |
-- |
3.15/5/6.3/8/10 |
-- |
||
Rated frequency |
50/60Hz |
|||||
Distribution circuit |
IT system: 4/5 channels AC220V |
IT system:8 channels AC220V |
||||
-- |
TN-S system: 1AC380V, 8AC220V |
|||||
IP Level |
IP31 |
IP34D |
IP31 |
IP34D |
||
Installation |
Grounded |
Embedded |
Grounded |
Embedded |
||
Inlet and Outlet Line |
Bottom Inlet and output |
Both bottom and top have access lines |
Bottom Inlet and output |
Both bottom and top have access lines |
||
Communication |
RS485 interface, Modbus-RTU protocol |
Dimension
GGF-IXF Series Dimensions & GGF-OXF Series Dimensions
GGF-IXQ Series Dimensions& GGF-OXQ Series Dimensions
GGF-IXG Series Dimensions&GGF-OXGA/GGF-OXG Series Dimensions
Structure
Application
GGF-O10A Isolation power cabinet system diagram
GGF-I8 Isolation power cabinet system diagram
Projects
1. Acrel Medical Isolated Power Supply System in Luanda General Hospital, Angola
2. ACREL Hospital Isolated Power Supply Application in Malaysia
Acrel Medical IT System Insulation Monitoring and Fault Location Products Selection Table V1.0
Note:“□”is optional,“—”is not optional,“■”is selection.
Medical Single Phase Isolation Transformer |
AITR-3150 |
AITR-5000 |
AITR-6300 |
AITR-8000 |
AITR-10000 |
Capacity |
3150VA |
5000VA |
6300VA |
8000VA |
10000VA |
|
□ |
□ |
□ |
□ |
□ |
Insulation monitor |
AIM-M10 |
AIM-M100 |
AIM-M200 |
|
|
Power supply |
|||||
AC220±10% |
|
□ |
|
|
|
AC85~265V DC100-300V |
□ |
|
|
|
|
DC24V |
|
|
□ |
|
|
Communication |
|||||
RS485 |
□ |
|
|
|
|
RS485+RS485 |
|
□ |
|
|
|
RS485+CAN |
|
|
□ |
|
|
Output |
|||||
DO1(over temperature) |
□ |
|
|
|
|
DO1(over temperature) DO2(alarm) |
|
|
□ |
|
|
DO1(over temperature) DO2(alarm) DO3(programmable)
|
|
□ |
|
|
|
1 channel DC24V |
□ |
|
|
|
|
Support fault location |
|||||
No |
□ |
□ |
|
|
|
Yes |
|
|
□ |
|
|
Power supply |
ACLP10-24 |
HDR-60-24 |
|
|
|
Insulation monitor |
|||||
AIM-M100 |
□ |
|
|
|
|
AIM-M200 |
|
□ |
|
|
|
Alarm indicator |
AID10 |
AID120 |
AID150 |
AID200 |
|
Display |
|||||
LED |
□ |
□ |
|
|
|
LCD |
|
|
□ |
□ |
|
Multi-machine display |
|||||
No |
□ |
□ |
|
|
|
Yes |
|
|
□ |
□ |
|
|
|||||
Current transformer |
AKH-0.66P26 |
|
|
|
|
|
■ |
|
|
|
|
Test signal generator |
ASG150 |
|
|
|
|
Support fault location |
|
||||
No |
— |
|
|
|
|
Yes |
■ |
|
|
|
|
Fault locator |
AIL150-4 |
AIL150-8 |
|
|
|
Support fault location |
|
||||
No |
— |
— |
|
|
|
Yes |
□ |
□ |
|
|
|
Locate number of channels |
|
||||
<=4 |
□ |
|
|
|
|
>4; <8 |
|
□ |
|
|
|
>8 Note 1 |
□ |
□ |
|
|
|
Other |
|
|
|
|
|
Note: 1. More than 8 channels can be freely combined, and the maximum support 24 locate channels.
Ordering example
Example 1: Isolation transformer 8kVA; AC220V; Insulation monitoring; Operating room LCD display; DO output programmable,According to the selection table, confirm the model is AITR-8000, AIM-M100, ACLP10-24, AKH-0.66P26, AID150.
Example 2: Isolation transformer 10kVA; Insulation monitoring; Fault location; ICU LCD display; DO output; Locate 12 loops;
According to the selection table, confirm the model is AITR-10000, AIM-M200, HDR-60-24, AKH-0.66P26, AID150, ASG150, AIL150-4, AIL150-8