● Communication management: Support Modbus RTU, Modbus TCP, IEC 60870-5-101, IEC 60870-5-103, IEC 60870-5-104, MQTT and other communication protocols
● Edge computing
● Strategy management
● System security
● Operational safety
General
Acrel ACCU-100M Microgrid Coordination Controller is a modular intelligent coordination controller applied to microgrid, distributed power generation, energy storage and other fields. ACCU-100M microgrid coordination controller is a modular intelligent coordination controller applied in the field of microgrid, distributed power generation and energy storage.
The device meets the system requirements for the access of photovoltaic system, wind power generation, energy storage system and charging piles, etc. It monitors the operation status and health condition of photovoltaic, wind power generation, energy storage system and charging piles through round-the-clock data collection and analysis of the microgrid system, and on the basis of which, with the target of safe and economic optimisation of operation, it obtains the optimal control strategy and then implements the regulation and control on the microgrid, realising real-time dynamic regulation function of the distributed energy.
It can achieve real-time dynamic regulation of microgrid distributed energy, energy storage system and load, promote localised consumption of new energy, improve the stability of grid operation and compensate for load fluctuations; effectively implement demand management of microgrid, improve the operating efficiency of microgrid, reduce the cost of power supply, and guarantee the safe, reliable and economic operation of microgrid.
Model Selection
Dimension

Typical Connection
| Project | Specifications |
| CPU | ARM Cortex-A7 528MHz |
| Memory | 256MB DDR3 + 256MB NAND Flash |
| Frequency andPower Consumption | 50 Hz (45 Hz~65 Hz), Power consumption ≤10 W |
| Supply Voltage | DC 9-36V |
| RS-485 Serial Port | 4-channel optocoupler isolation + 1-channel RS232 (debug port) |
| RJ45 Ethernet Port | 2-Channel 10/100M Adaptive |
| USB HOST | 1-Channel USB 2.0 High-Speed Interface, supporting connection of USB drives for breakpoint resume (resumable transmission) or wireless Wi-Fi network adapter(optional) |
| TF Card Interface | Supports hot-plug-and-play and plug-and-play data storage. |
| DI Acquisition | 8 passive dry contact switch inputs |
| RST Button | Short press for 2-5 seconds to restart the device, long press for more than 5 seconds to restore the factory default settings. |
| Protocol Support |
Device side: Modbus Rtu/TCP, DL/T 645-1997, DL/T 645 and others;
Master side: Modbus TCP, 104, SNMP, MQTT protocol, etc; |
| Environment | Operating Temperature:-20℃~+55℃ |
| Storage and Transportation Temperature:-25℃~+70℃ | |
|
Relative Humidity:≤95%(+25℃) |
|
|
Altitude:≤2500m |
Slave Module Technology Table
|
ACCU-M485 Module |
Power Supply | RJ45 Interface, powered by the Main Module. |
|
Communication |
Uplink: RJ45 Interface, communicating with the Main Module.Downlink: 4-Channel Optocoupler-Isolated RS485 | |
|
ACCU-M4G Module |
Power Supply | RJ45 Interface, powered by the Main Module. |
|
Communication |
Uplink: 2G/4G Full-Netcom
Downlink: RJ45 Interface, communicating with the Main Module. |
|
|
ACCU-MIO Module |
Power Supply | RJ45 Interface, powered by the Main Module. |
|
Communication |
Uplink: RJ45 Interface, communicating with the Main ModuleDownlink: 8 Digital Inputs (Passive) / 4 Digital Outputs (Passive) / 4 Analog Inputs (4-20mA) | |
|
ACCU-MSE Module |
Power Supply | RJ45 Interface, powered by the Main Module. |
|
Communication |
Uplink: RJ45 Interface, communicating with the Main Module Hardware Encryption Module: Supports encryption algorithms including SM1, SM4, DES, 3DES128, AES128, AES192, AES256, RSA1024, RSA1280, RSA2048, and others. |