AID150 Remote Alarm Indicator
● Remote monitoring
● LED indicators: On, Insulation, Overload, Overtemp
● Mute button
● Test button
● Auxiliary power supply: DC24V
● RS485(MODBUS-RTU)
  • product detail
  • SELECTION Table
  • ISOLATION POWER CABINET

General

AID Series alarm and display device is remote display and sound and light alarm device by using advanced fieldbus communications technology. AID Series alarm and display device have four models: AID10, AID120, AID150 and AID200. Products are classified according to the installation method and display. The device can be installed on the operating room or information control panel of intensive care unit, the medical staff can easily know the status of medical isolated power systems, and the type of fault when the system fails.

AID150 centralized alarm and display instrument adopts the LCD liquid crystal display and achieves data exchange with AIM-M200 medical intelligent insulation monitoring instrument through CAN communication interface of self-defined protocol, which can real-time monitor multi-channel data of AIM-M200 medical intelligent insulation monitoring instrument.


Function

* Can read and display monitoring data and alarm information of insulation monitor in real-time by bus communication

* Can set the alarm parameters of insulation monitor remotely

* When the system fails, products can generate sound and light alarm, if you press the mute button, the sound can be turned off, but the corresponding fault indicator does not go out until the fault is removed so far.


Specification

Model

Parameter

AID10

AID120

AID150

AID200

Auxiliary power

Voltage

DC24V

Consumption

0.6W

Insulation resistance Measurement range

--

0-999KΩ

--

--

Insulation alarm value range

--

50-999KΩ

--

--

Transformer load rate display

--

Percentage display

--

--

Load current alarm value settings

--

14A,18A, 22A, 28A, 35A, 45A

Temperature alarm value range

--

0-200℃

Alarm

Sound and light alarm

Alarm type

Insulation fault, overload, over-temperature, equipment failure

Communication

RS485 interface, Modbus-RTU protocol

Display

--

LED display

LCD display

LCD display



Dimension


Display


Application


Wiring and Installation

Terminal Description

Note: The 24V power supply can be connected by multiple copper wires of 2x1.5mm2, and the RS485 communication terminal can be connected by shielded twisted pair of 2x1.5mm2


Installation



Common Problems

For common problems, the causes can be determined and the faults can be eliminated according to the phenomenon of each instrument and the fault types:

Fault phenomenon

Possible causes and troubleshooting

The instrument is not lit.

The 24V power supply is not connected well. Check the wirings of 24V and G terminals and rewire.

Communication indicator does not flash

In the system, the AIM-M monitor communication line is not connected properly. Check the communication line and confirm whether the matching resistance is connected properly.


Note: If the above faults occur, interrupt the power to troubleshoot, and adjust the wirings until everything is normal

Acrel Medical IT System Insulation Monitoring and Fault Location Products Selection Table V1.0

Note“□”is optional“—”is not optional“■”is selection.

Medical Single Phase Isolation Transformer

AITR-3150

AITR-5000

AITR-6300

AITR-8000

AITR-10000

Capacity

3150VA

5000VA

6300VA

8000VA

10000VA

Insulation monitor

AIM-M10

AIM-M100

AIM-M200

Power supply

AC220±10%

AC85~265V

DC100-300V

DC24V

Communication

RS485

RS485+RS485

RS485+CAN

Output

DO1(over temperature)

DO1(over temperature)

DO2(alarm)

DO1(over temperature)

DO2(alarm) DO3(programmable)

1 channel DC24V

Support fault location

No

Yes

Power supply

ACLP10-24

HDR-60-24

Insulation monitor

AIM-M100

AIM-M200

Alarm indicator

AID10

AID120

AID150

AID200

Display

LED

LCD

Multi-machine display

No

Yes

Current transformer

AKH-0.66P26

Test signal generator

ASG150

Support fault location

No

Yes

Fault locator

AIL150-4

AIL150-8

Support fault location

No

Yes

Locate number of channels

<=4

>4; <8

>8 Note 1

Other

Note: 1. More than 8 channels can be freely combined, and the maximum support 24 locate channels.


Ordering example

Example 1: Isolation transformer 8kVA; AC220V; Insulation monitoring; Operating room LCD display; DO output programmable,According to the selection table, confirm the model is AITR-8000, AIM-M100, ACLP10-24, AKH-0.66P26, AID150.
Example 2: Isolation transformer 10kVA; Insulation monitoring; Fault location; ICU LCD display; DO output; Locate 12 loops;
According to the selection table, confirm the model is AITR-10000, AIM-M200, HDR-60-24, AKH-0.66P26, AID150, ASG150, AIL150-4, AIL150-8



Feedback form contact with us
Related Product
Ground Fault Detection And Location Relay
Ground Fault Detection And Location Relay
Quality Ground Fault Detection And Location Relay manufacturers & exporter - buy Ground Fault De...
Learn More
ASG150 Test Signal Generator
ASG150 Test Signal Generator
You can buy good quality ASG150 Test Signal Generator, we are the best distributor from China market...
Learn More
ACLP10-24 DC Power Supply
ACLP10-24 DC Power Supply
Acrel is the best ACLP10-24 DC Power Supply manufacturer in China. Offering quality product to globa...
Learn More
Product Catalog