Single Phase PV Inverter Energy Meter ACR10R-D16TE

● Type: ACR10R-D10TE, ACR10R-D16TE, ACR10R-D24TE, ACR10R-D36TE
● Current input: 80A, 120A, 200A, 300A
● Measurement current、voltage、active power, reactive power, power factor
● RS485 communication interface
● The interfaces with switch input and relay output
● LCD display

  • product detail
  • PARAMETER

General

ACR10R-D16TE din rail energy meter with split core open ct clamps is suitable for power monitoring of grid-connected PV power station, power demand side management and otherapplications. It is special designed for solar inverters. It can measure electrical parameters including current, voltage, active power, reactive power, apparent power, frequency, power factor and so on.

It supports multi-tariff energy metering, 4 quadrant energy metering, harmonic analyse and energy monitoring. Circuit breaker switch 'remote signaling' and 'remote controlling' can be realized with digital input and relay output.


Specification

Model Function
ACR10R-DxxTE
Measurement
Parameters
Single-phase current
YES
Single-phase voltage
YES
Single-phase (active power, reactive power, power factor)
YES
Three-phase (active energy, reactive energy)
YES



Wiring




Dimension

Shape and installing size (unit: mm)


Size of open type transformer(unit: mm)


Roche coil mounting method


Typical Connection

Input

Grid

Single Phase

Frequency

45~65Hz

Voltage

Rated voltage: AC 100V, 400V

Overload: 1.2 times the rated voltage(continuous); 2 times the rated voltage lasting for 1 second

Power consumption: less then 0.2VA

Current

Rated current: 10A, 20A, 40A. 80A, 120A, 200A etc.

Overload: 1.2 times the rated current(continuous); 10 times the rated current lasting for 1 second

Power consumption: less then 0.2VA

Output

Communication

RS485 interface, Modbus-RTU

Display

LCD

Measurement precision

Voltage: 0.2 level, current, power Active energy: 0.5 level,0.01Hz frequency, Reactive energy: 1 level

Power supply

AC85~265V or DC100~350V; power consumption ≤10VA

Safety

Power frequency withstand voltage


AC2kV 1 min between power supply // current input//voltage input and communication
AC2kV 1 min between each pair of combinations among power supply, current input and voltage input.


Insulating resistor

Input, output terminal to housing >100MΩ


Environment


Working temperature: -10℃~+55℃; Storage temperature: -20℃~+70℃
Relative humidity: 5%~95%, non-condensing; Altitude: ≤2500m



Feedback form contact with us
Related Product
Single Phase Modbus Energy Meter ADL10-E
Single Phase Modbus Energy Meter ADL10-E
Hot Single Phase Modbus Energy Meter ADL10-E - Acrel is the best Single Phase Modbus Energy Meter AD...
Learn More
Single Phase Rail Mounted Energy Meter ADL100-ET
Single Phase Rail Mounted Energy Meter ADL100-ET
Acrel is the best Single Phase Rail Mounted Energy Meter ADL100-ET manufacturer in China. Offering q...
Learn More
Din Rail Modbus Single Phase kWh Meter ADL200
Din Rail Modbus Single Phase kWh Meter ADL200
You can buy good quality Din Rail Modbus Single Phase kWh Meter ADL200, we are the best distributor ...
Learn More
Product Catalog