Smart Busway Monitoring Solution
Smart Busway Monitoring Solution
Smart Busway Monitoring Solution
Mar 8, 2021
Share:
Application
It is necessary to real-time monitor energy consumption and power quality of end load in smart track busway. Data can be uploaded to monitoring system by local touch screen through RS485 and it can realize real-time monitoring of the whole power distribution system. At the same time, it can monitor real-time temperature at the busway connector and plug-in box interface to ensure safe and reliable operation of the busway.


Structure


Main Functions

1.AMB100 or AMB110 is usually installed in the busbar start box and plug-in box
2.Measurement: AC or DC busbar voltage, current, harmonics and other parameters.
3.Realize temperature monitoring of the busbar plug interface
4.AMB200 is usually installed at the connector of the dense AC busbar, and can monitor temp. and humidity at the connector.
5.Communication: LoRa or RS485


Product Selection

  • ATP010kt

    10 inch touch screen
    Real-time monitoring and display voltage, current, power, energy, power quality, switch status, wave curve, etc. of the busbar monitoring device alarm, communication and other parameters can be configured on the screen.
    2 RS485 and 1 Ethernet, and data can uploaded by RS485 or RJ45 communication
  • AMB100-A-P1

    Installation: DIN Rail 35mm
    Measurement: 3 phase electrical parameters, 2DI2DO, 8 temp., 1 leakage current, 1 temp. and humidity
    Communication: 1 in 1 out type RJ45 interface(Modbus protocol)
  • AMB110-A-P1

    1.Installation: DIN Rail 35mm
    2. Measurement: 3 phase electrical parameters, 2DI2DO, 4 temp., 1 leakage current, 1 temp. and humidity
    3. Communication: 1 in 1 out type RJ45 interface(Modbus protocol)
  • AMB100-D-P1

    Installation: DIN Rail 35mm Measurement: 1 DC circuit electrical parameters, 4DI2DO, 8 temp., 1 leakage current, 1 temp. and humidity ±12V output to power hall current sensor Communication: 1 in 1 out type RJ45 interface(Modbus protocol)
  • AMB110-D-P1

    Installation: DIN Rail 35mm
    Measurement: 3 DC circuits electrical parameters, 4DI2DO, 4 temp., 1 leakage current,1 temp. and humidity
    ±12V output to power hall current sensor
    Communication: 1 in 1 out type RJ45 interface(Modbus protocol)
  • AMB200-LR/AMB200-C

    Installation: Fixed on the cover of the busbar connection Contact temp. measurement, measure and display temp. of 4 AC busbars
    Communication: RS485 or LoRa
  • AHKC-BS

    Current ratio: 100A/5V
    Common Specification: 100A/5V

Photos on Site

Solution
Product Catalog