Closed Loop Hall Current Sensor AHBC-LTA

● Model: AHBC-LTA

● Rated current input: 100-300A

● Rated output: 50mA / 100mA

● Aperture: 20mm

● Power supply: ±15V


  • product detail
  • parameter
General

Closed-loop Hall current sensor is also called Hall magnetic balancing current sensor. It incorporates the mentioned theory with magnetic balancing theory. In other words, the ferromagnetic field concentrator concentrates the magnetic field generated by primary current and applies it to the Hall component. Then the voltage signal output from Hall component is amplified and becomes the input of power amplifier. The offset current output flows through the secondary compensating coil.

The magnetic field generated by secondary coil is opposite to the field generated by primary current. In such way, the primary field is compensated and the Hall output is reduced gradually. When the primary field is equivalent to thesecondary one and the offset current keeps stable, it is the magnetic balancing.This circuit mainly consists of electromagnetism conversion component, circuit amplifier and drive compensating circuit.

initpintu_副本


Selection table

Type

Rated current

Rated output

Aperture

Power Supply

AHBC-LTA

100A-300A

50mA/100mA

Φ20mm

±15V

AHBC-LT1005

1000A

200mA

/

±12V-±24V

AHBC-LF

2000A

400mA

/

±12V-±24V


Dimension

Spec. and size (unit:mm)

2


Size Specification

Outline size(mm)

Through size(mm)

Figure

AHBC-LTA

68*57*20.5

Φ20mm

Fig.2

AHBC-LT1005

119*112*40

Φ40mm

Fig.2

AHBC-LF

155*135*45

Φ60mm

Fig.2



Wiring


Notes:
1. When the hall sensor is used, in order to obtain better dynamic characteristics and sensitivity, attention must be paid to the coupling between the primary side coil and the secondary side coil. It is recommended to use a single wire and the wire completely fills the hall sensor module wire hole;
2. When the hall sensor is used, the best measurement accuracy can be obtained under the rated input current value. When the measured current is far lower than the rated current To obtain the best accuracy, multiple turns can be used for the primary side, i.e. IPNP = rated ampere turns. In addition, the temperature of the primary side feeder shall not exceed 80 ℃;
3. The auxiliary power supply of Hall current sensor shall not exceed ± 20% of the calibrated value when it works normally;
4.Hall current sensor shall not fall from a high place (≥ 1m) during installation and use;
5. It is unable to adjust the zero point and full degree adjustment potentiometer;
6. Auxiliary power supply needs to be configured by itself;

7. The positive and negative poles of the power supply cannot be reversed.


Related Solution

Hall Effect Sensor Solution

Type

Rated current

Rated output

Measuring Aperture

Power Supply

AHKC-E

0-(50-500)A

5V/4V

Φ20mm

±15V

AHKC-EA

0-(200-1000)A

5V/4V

Φ40mm

±15V

AHKC-EB

0-(500-1500)A

5V/4V

Φ60mm

±15V

AHKC-LT

0-(100-800)A

5V/4V

Φ32.5mm

±15V

AHKC-C

0-(100-800)A

5V/4V

31*13

±15V

AHKC-BS

0-(50-500)A

5V/4V

20.5*10.5

±15V

AHKC-BSA

DC0-(50-500)A

4-20mA

20.5*10.5

12V/24V

AHKC-F

0-(200-1000)A

5V/4V

43*13

±15V

AHKC-FA

0-(200-1500)A

5V/4V

52*15

±15V

AHKC-HAT

0-(400-2000)A

5V/4V

52*32

±15V

AHBC-LTA

100A-300A

50mA/100mA

Φ20mm

±15V

AHBC-LT1005

1000A

200mA

/

±12V-±24V

AHBC-LF

2000A

400mA

/

±12V-±24V

Feedback form contact with us
Related Product
Split Core Hall Effect Current Sensor AHKC-EKA
Split Core Hall Effect Current Sensor AHKC-EKA
Acrel is one of the toppest Hall Effect Sensor,Acrel Hall Sensor,Split Core Hall Effect Current Sens...
Learn More
Open Loop Hall Effect Current Sensor AHKC-EKB
Open Loop Hall Effect Current Sensor AHKC-EKB
You can buy good quality Open Loop Hall Effect Current Sensor AHKC-EKB, we are the best distributor ...
Learn More
Open Type Hall Current Sensor AHKC-EKC
Open Type Hall Current Sensor AHKC-EKC
As the best China Open Type Hall Current Sensor,Split Core Hall Effect Current Sensor,Hall Effect Cu...
Learn More
Product Catalog